Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement

The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications.

It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.


• Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

• Modular concept for easy replacement of display or electronics

• Seamless and independent system integration (HART/PA/FF)

• Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

• International usage thanks to a wide range of approvals


For level and/or pressure measurement.

• Process connections: Thread, flanges and flush-mounted hygienic connections

• Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

• Measuring range: 0.1 to 10bar (1.5 to 150psi)

• Accuracy: ±0.2%, ±0.1% (option)

• International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates

 
Download the complete technical features
  • Measuring principle : Hydrostatic
  • Accuracy : Standard 0,2%, Optional 0,1%
  • Long term stability : 0,05% of URL/year
  • Ambient temperature : -40°C...85°C (-40°F...185°F)
  • Process temperature : -10°C...100°C (14°F...212°F)
  • Pressure measuring range : 100mbar...10bar (1.5psi...150psi)
  • Max. measurement distance : 100m (328ft) H2O
  • Safety approvals : Overfill prevention WHG SIL
  • Marine approval : GL/ ABS/ LR/ BV/ DNV
  • Drinking water approvals : KTW/ NSF/ ACS
 

Opinion on Hydrostatic Level measurement | Deltapilot FMB50

Give your opinion / Ask a question

Drop
your rating

Your answer to the rating from du

Expo permanente
ENDRESS+HAUSER SAS

ENDRESS+HAUSER SAS

     

Cookies ensure the proper functionning of our sites and services. Using these, you accept the use of cookies.

OK

Find out more

Find your suppliers

Complete your request and let our teams find you the best deals available.

Submit your query

Find your future clients

List your products and services to enhance your web presence and receive qualified enquiries.

Exhibit your products